eVmP2 dual-channel valveless metering pump enclosure with two pump heads on a production line

Dual Metering

eVmP2 Dual Valveless Metering Pump System

Two Configurable eVmP Dispensers in One Enclosure

The eVmP2 is a dual enclosure that configures two eVmP dispensers in one system. It is a programmable, automated electronic variable metering pump arrangement for fluid dispensing and metering, designed around two compatible pump modules rather than a single standalone pump head.

Compatible M-series configurations reach up to 0.10 mL per revolution and 100 mL/min, V-series configurations up to 1.28 mL per revolution and 1,280 mL/min, and VS-series configurations up to 1.28 mL per revolution and 1,920 mL/min. Installed pump equipment determines the applicable range.

The eVmP Smart Pump system uses a valveless ceramic-piston design and touchscreen interface to set fluid-control parameters. Two precision stepper motors adjust pump volume and speed, while stroke rate and displacement are independently controlled for the selected configuration.

The eVmP2 supports Ethernet TCP/IP and RS485 communication, with operational modes for continuous metering, single or multiple dispense, flow direction and suck back. Zaxis provides configurable eVmP solutions through its in-house engineering and development team for automation applications.

Request for Quote

Dispense Rate Calculator

Why Choose the eVmP2 Dual Enclosure?

The eVmP2 brings two eVmP dispensers into one configurable enclosure for fluid dispensing and metering. It is intended for applications that need two controlled pumping functions in one system, with a touchscreen interface for setting fluid-control parameters.

The eVmP2 supports custom smart-pump solutions through Zaxis engineering and development. Media compatibility, wetted-path options and selected M-, V- or VS-series equipment should be matched to the process before configuration. The dual system uses two precision stepper motors for pump-volume and speed adjustment, plus patented automatically adjusted dispense volume. Its interface and stored-program functions support repeatable setup of the configured two-pump arrangement, while in-house engineering can develop a custom eVmP smart-pump solution for the specific application.

eVmP2 dual enclosure on a production line and in a laboratory
2
eVmP Dispensers

Two compatible eVmP pumping functions in one enclosure.

Up to 50
Stored Programs

Multiple parameters can run through a single pump.

±1%
Full-Scale Accuracy

eVmP2 accuracy with 0.5% CV.

Up to 1,920 mL/min
VS-Series Flow

Compatible VS-series system maximum.

-20ºC–70ºC
Operating Temperature

Non-condensing operational temperature range.

M-Series metering-pump tubing on a production line

eVmP2 Dual-Enclosure Benefits

The eVmP2 is built for configurable dual dispensing rather than a single-pump enclosure. The system pairs two precision stepper motors with electronic volume adjustment, stored programs and communication options so a configured pair of eVmP pump modules can address fluid-control work in one enclosure.

  • ✓Two compatible eVmP dispensers in one enclosure.
  • ✓Millions of maintenance-free cycles stated for the ceramic internals.
  • ✓1% accuracy or better with no drift as stated for the system.
  • ✓Two precision stepper motors for pump-volume and speed adjustment.
  • ✓Patented, automatically adjusted dispense volume.
  • ✓Independently controlled stroke rate and displacement.
  • ✓PC interface with control up to 128 pump modules, up to 50 programs and RS232/485 PLC communication.

How the eVmP Enclosure Dispenses

The enclosure provides the control interface for a compatible eVmP pump head. The valveless cycle uses a piston to move fluid; the compatible head and selected operating program determine the dispensing task.

1

Aspirate

The piston draws fluid in as the cycle begins.

2

Rotate and Seal

The piston’s rotation seals the inlet as described for the eVmP valveless pumping principle.

3

Dispense

The piston dispenses the selected fluid volume through the compatible pump head.

4

Repeat

The programmed system repeats the cycle for continuous metering or single and multiple dispense operations.

For an overview of the eVmP interface and operation, see the eVmP Smart Pump Interface Overview video in the resources below.

Applications for eVmP Metering

The eVmP platform is used where a configured pump system is needed for controlled fluid dispensing. The enclosure should be paired with compatible M, V or VS10-series equipment and application-appropriate wetted-path materials.

Diagnostic reagent dispensing

Controlled dispensing for diagnostic reagent applications.

Read more →

Buffer dispensing

Automated dispensing considerations for buffers and diagnostic workflows.

Read more →

Pharmaceutical filling

Fluid metering options for pharmaceutical manufacturing.

Read more →

Chemical metering

Configured pump systems for chemical metering applications.

Read more →

Analytical instruments and OEM equipment

eVmP configurations for manufacturing and OEM instrumentation.

Read more →

Electronics fluid metering

Fluid dispensing applications for electronics manufacturing.

Read more →

Technical Specifications

These are eVmP2 system and compatible-series specifications. The chosen M-, V- or VS-series pump equipment and wetted-path material determine the final process configuration.

eVmP2 dual enclosure with two eVmP pump heads mounted
Media Compatibility
Most acids and bases, water-like to slurry, monomers and some polymers
Wetted Path Options
Ceramic (medical-grade alumina oxide), 316SS, 303/304SS, PVDF, PEEK; customization available
Operational Temperatures
-20ºC–70ºC, non-condensing
Operational Types
Continuous metering, single/multiple dispense, flow direction and suck back
Stored Programs
Up to 50
Interface
Ethernet TCP/IP, RS485 1/2 or full duplex
Accuracy
+/- 1% full scale, 0.5% CV
M-Series Compatibility
100 PSIG; up to 0.10 mL/rev; up to 100 mL/min; 1000 RPM
V-Series Compatibility
100 PSIG; up to 1.28 mL/rev; up to 1280 mL/min; 1000 RPM
VS-Series Compatibility
200 PSIG; up to 1.28 mL/rev; up to 1920 mL/min; 1500 RPM

Compare the
eVmP Range

Choose the eVmP2 for two configurable eVmP dispensers in one enclosure. Choose a compatible M, V or VS-series pump arrangement based on the needed displacement, flow, pressure and wetted path; select the eVmP1 when a one-pump benchtop enclosure is appropriate.

Comparison source: Specifications from the Zaxis eVmP product pages. The installed pump head and drive set the working range; confirm the configuration with Zaxis.
SpecificationZaxis eVmP M-Series microliter metering pumpM-SeriesV-Series milliliter metering pump head and stepper driveV-SeriesZaxis eVmP VS10-Series milliliter metering pumpVS10-SeriesZaxis eVmP1 benchtop enclosureeVmP1 BenchtopZaxis eVmP2 dual enclosureeVmP2 Dual
FormatPump head + OEM drivePump head + OEM drivePump head + servo driveBenchtop enclosure, 7″ touchscreenDual enclosure, two pumps
Volume per revolution / stroke2.5–100 µL25 µL–1.28 mLNearly 10 mL per strokeUp to 1.28 mL (installed head)Up to 1.28 mL (installed heads)
Maximum flowUnder 100 mL/minUp to 1,920 mL/min (VS drive)Up to 6 L/min (10 mL/rev @ 600 RPM)Up to 900 mL/minUp to 1,920 mL/min (VS-Series)
Maximum pressure100 PSIG100 PSIG (V) / 200 PSIG (VS)100 PSIG0–100 psi100 PSIG (M/V) / 200 PSIG (VS)
Accuracy / repeatability±1% FS / 0.5% CV±1% FS / 0.5% CV±1% FS / 0.5% CV±1% FS / 0.5% CV±1% FS / 0.5% CV
Wetted pathCeramic, PVDF (Kynar®), PTFE, Rulon® ARCeramic, 316SSCeramic, 316SS, PTFE; sanitary fittingsCeramic, 316SS, 303/304SS, PVDF, PEEKCeramic, 316SS, 303/304SS, PVDF, PEEK
DriveStepper (VMP-OEM-M)Stepper (VMP-OEM-V) or servo (VMP-OEM-VS)Servo (VMP-OEM-VS10)M/V stepper or servo driveTwo stepper drives
InterfaceRS485, PLC I/O, optional EtherNet/IPRS485, PLC I/O, optional EtherNet/IPRS485, PLC I/O, optional EtherNet/IPRS485, 24 VDC I/O, optional EtherNet/IPEthernet TCP/IP, RS485
Stored programsUp to 50Up to 50Up to 50Up to 50 per driveUp to 50

eVmP2 Dual Enclosure FAQ

What is the eVmP2?

The eVmP2 holds two eVmP dispensers in one programmable enclosure for fluid dispensing and metering.

How many pumps does it support?

The eVmP2 contains two compatible eVmP pump modules. The selected modules establish the final process arrangement.

Which pump series are compatible?

The eVmP2 supports M-, V- and VS-Series equipment. M- and V-Series reach 100 PSIG, while VS-Series reaches 200 PSIG.

What communication interfaces are available?

The eVmP2 provides Ethernet TCP/IP and RS485 one-half or full duplex. It also supports RS232/485 PLC communication and PC interface control for up to 128 pump modules.

How many programs can it store?

The eVmP2 stores up to 50 programs and can run multiple parameters through a single pump.

What fluids can it handle?

Media compatibility includes most acids and bases, water-like fluids to slurry, monomers and some polymers. Confirm the media and selected wetted-path materials with Zaxis.

What applications use the dual system?

The eVmP2 dispenses active pharmaceutical ingredients, diagnostic-kit reagent, battery electrolyte and medical-device coating, lubrication or adhesives. Pump heads and wetted-path materials must suit the application.

What accuracy is specified?

The eVmP2 delivers +/- 1% full-scale accuracy with 0.5% CV. It operates from -20ºC to 70ºC, non-condensing.

Ready to Ensure Product Integrity ?

Request for Quote