Metered Volume Fill Pressure Decay
To leak test a sealed component, a chamber test is used. Place the part in a custom build nest and seal the chamber closed. Fill the chamber with a metered volume to a desired pressure. Then proceed with a standard pressure decay test. Any drop in pressure beyond a designated limit signifies a leak into the sealed part under test.
Related tutorials

Zaxis Multi-Lumen Catheter Testing
This video shows a multi-lumen fixture for catheter testing using a skive sealer.

Starting a Test: Pressure Decay Leak Testing – Part 5
In Part 5 of the Zaxis Pressure Decay Series, we move from setup to action: running your first leak test and using it to define a baseline for good parts. – Run an…

Test Volume and Cycle Time: Pressure Decay Leak Testing – Part 4
In Part 4 of the Zaxis Pressure Decay Series, you’ll learn how test volume affects pressure decay results, test timing, and overall production efficiency. You’ll learn…