Differential Pressure Leak Test process graph showing the programmed test stages and pass/fail responseZaxis Z8 air leak tester showing a production test screen

Leak Test Method

Differential Pressure Leak Test

A differential pressure test compares the pressure in a test part with a pre-established reference air volume to detect pressure differences caused by leakage.

Differential pressure testing is a form of pressure-decay testing that compares two pressure readings: the test-part volume and a pre-established reference volume. Differential pressure transmitters send those readings to a manometer, which evaluates their difference.

The part connects to the tester through fittings or fixtures and fills with air. After reaching the selected pressure, the system stabilizes to account for stretching, flexing or other changes before relative pressure is measured.

The method suits components with large volumes and low leak rates. Applications include automotive equipment, industrial components, consumer goods, medical parts, electronic devices and packaging lines.

Request for Quote

Leak Rate Calculator

How is Leak Rate Calculated →

What is a differential pressure leak test?

Differential pressure testing compares a test part with a reference volume instead of relying on a single pressure reading. Both volumes are established at test pressure, and the tester monitors the relative pressure between them.

During stabilization, the fill valve remains closed so the part can settle. If pressure drops in the test part, the resulting difference from the reference volume becomes the basis for a production decision.

After the test, remaining pressure is flushed from the system. A green indicator represents a part within its pre-set specifications, while a red indicator represents a failed part.

How a differential pressure test runs

1

FILL BOTH

Connect the part and fill it with air to the pre-determined test pressure while establishing the reference volume.

2

SETTLE

Keep the fill valve closed while the part stabilizes to account for stretching, flexing or other changes.

3

TEST

Monitor relative pressure between the part and the reference volume with differential pressure transmitters.

4

VENT

Flush remaining pressure from the system when the differential pressure test is complete.

A part within its pre-set differential-pressure specification passes; a pressure drop that exceeds the specification fails.

When differential pressure is the right method — and when it is not

Differential pressure is a fit when

  • ✓Large-volume components with low leak rates
  • ✓A non-destructive production test
  • ✓A test part that can connect through fittings or fixtures
  • ✓A need to compare a part with a reference air volume

Sensitivity, cycle time and part volume

The reference volume distinguishes this method. After fill and stabilization, differential pressure transmitters monitor the relative pressure between that volume and the test-part volume.

Stabilization accounts for stretching, flexing and other changes before relative pressure is evaluated, with the fill valve closed throughout the process.

Differential pressure testing suits large volumes with low leak rates. The Isaac HD and Zaxis 7i both run differential-pressure sequences.

By comparing the stabilized part with the reference volume, the test evaluates relative pressure change rather than a single pressure reading. The programmed specification converts that measurement into a clear, non-destructive pass/fail decision.

Differential pressure test schematic showing a test part and reference volume

Which Zaxis testers run differential pressure

Differential pressure needs a tester that manages a reference volume alongside the part. These Zaxis testers run the differential-pressure sequence.

Applications for differential pressure testing

Automotive equipment

Automotive equipment

Differential pressure testing is used for automotive equipment.

Industrial components

Industrial components

Large-volume industrial components can be evaluated against a reference volume.

Medical parts

Medical parts

Medical parts with large internal volumes are tested against a reference volume.

Electronic devices and packaging

Electronic devices and packaging

Electronic devices and packaging lines use the reference-volume comparison for low leak rates.

Differential pressure vs other leak test methods

Highlighted row is this method. ✓ yes · × no
MethodNon-destructiveNeeds an access portLocates the leakTypical use
Pressure decay✓✓×Sealed parts with a port
Vacuum decay✓✓×Parts and packaging
Mass flow✓✓×Flow-rate limits
Occlusion✓✓×Blocked passages
Burst×✓×Failure pressure
Pressure cracking✓✓×Valve opening pressure
Chamber✓××Sealed parts, no port
Sniffing✓✓✓Finding the leak site
Hard vacuum✓✓×Hermetic, safety-critical parts
Accumulation✓✓×Large parts, total leak rate
Bombing✓××Sealed parts, no fill port
Differential pressure✓✓×Large volumes, low leak rates
Trace gas✓✓✓Very small leaks, quantified

Differential pressure leak test FAQ

What is a differential pressure test?

It compares pressure in a test part with a pre-established reference volume to measure the difference between them.

How does differential pressure testing detect a leak?

A pressure drop in the test part creates a relative pressure difference from the reference volume.

Why is a reference volume used?

It provides the established air volume against which test-part pressure is compared.

What happens during settle?

The part stabilizes to account for stretching, flexing or other changes while the fill valve remains closed.

What parts suit differential pressure testing?

It is an ideal solution for components involving large volumes with low leak rates.

Is differential pressure testing destructive?

No. It is a non-destructive testing method.

What happens after the test?

Remaining pressure is flushed from the system, and the tester indicates pass or fail against the pre-set specification.

Ready to Ensure Product Integrity ?

Request for Quote