Trace Gas Leak Testing graph showing the test stages and reject limitZaxis Z-Charge and Z-Ion helium testing equipment

Helium Leak Test Method

Trace Gas Leak Testing

Trace gas leak testing fills a sealed part with an identifiable gas and measures the molecules that escape, producing a sensitive quantitative leak result.

Trace-gas leak testing fills a sealed part with a gas the detector can identify, then measures the gas that escapes. Helium, hydrogen forming gas, argon and clean dry air are options.

Because the instrument detects escaping molecules instead of inferring a leak from pressure change, trace-gas methods can find smaller leaks, locate a leak site and produce a quantitative, recordable leak rate.

Helium hard vacuum systems resolve 10⁻⁹ to 10⁻¹¹ mbar·l/s, and helium sniffing typically reaches about 10⁻⁷ mbar·l/s. Forming-gas sniff detection typically reaches about 10⁻⁷ mbar·l/s, argon-capable detectors roughly 10⁻⁶ mbar·l/s, and air-based detection roughly 10⁻⁴ mbar·l/s.

Request for Quote

Leak Rate Calculator

How is Leak Rate Calculated →

What is a trace gas leak test?

Trace-gas testing detects the selected gas outside a sealed part, not a pressure change over time. The detector and method determine whether the result measures total leakage, locates a leak or does both.

Helium is inert and non-flammable with low background. Forming gas is 5% hydrogen in 95% nitrogen for sniff detection, while argon and clean dry air are additional choices with compatible detection.

The method determines the result: sniffing follows seams and fittings to locate a leak; hard vacuum measures total leakage at maximum sensitivity; accumulation measures gas collected around a part; and bombing evaluates finished sealed devices without a direct connection.

A trace-gas result comes from detecting the selected gas outside the part, rather than measuring pressure change over time. The detector and method determine whether the result measures total leakage, locates a leak or does both.

Helium is an inert, non-flammable tracer with low background. Forming gas is 5% hydrogen in 95% nitrogen for sniff detection; argon and clean dry air are additional options with compatible detection. The choice follows the required sensitivity and method.

Trace-gas methods support different measurements: sniffing follows seams and fittings to find a leak; hard vacuum measures total leakage at maximum sensitivity; accumulation measures gas collected around a part; and bombing evaluates finished sealed devices without a direct connection.

How a trace gas test runs

1

FILL

Fill the sealed part with the selected trace gas at the programmed condition.

2

STABILIZE

Allow the part and test setup to reach the required measurement condition.

3

DETECT

Measure escaping trace gas with the selected detection method.

4

RECORD

Record the quantitative leak result and compare it with the programmed reject limit.

A result within the programmed reject limit passes; a result above the limit fails.

When trace gas is the right method — and when it is not

Trace gas is a fit when

  • ✓A need for a quantitative, recordable leak rate
  • ✓A sensitivity requirement beyond pressure-based methods
  • ✓A need to locate a leak with a sniffing method

Sensitivity, cycle time and part volume

Trace-gas detectors respond to the escaping gas itself, reducing the influence of temperature drift, part flexing and volume effects seen in pressure-decay testing.

Gas choice follows required sensitivity and operating constraints. Helium has low atmospheric background; forming gas is 5% hydrogen in 95% nitrogen; argon is an alternative; and compatible instruments can use clean dry air.

The method may be sniffing for location, hard vacuum for maximum sensitivity, accumulation for a total result in a chamber, or bombing for finished sealed parts without a direct connection.

The detector responds to the selected gas outside the part, not a pressure change inside it.

Select the gas and method together based on required sensitivity and compatible detection.

The method determines whether the result locates a leak, measures total leakage or provides both.

A programmed sequence keeps fill, stabilization, detection and result recording tied to the same part and selected method.

Trace-gas leak-test sequence diagram showing part charge and detector measurement

Which Zaxis testers run trace gas

Trace-gas testing pairs a charging system with a gas-specific detector. Z-Charge evacuates, purges and charges the part; Z-Ion detects the escaping helium.

Applications for trace gas testing

Medical devices

Medical devices

Trace-gas methods support sensitive, quantitative testing of sealed medical components.

Electronics and sensors

Electronics and sensors

Hermetic packages, sealed wearables and assemblies can use trace-gas detection.

Automotive and e-mobility

Automotive and e-mobility

Battery enclosures and thermal-management components can be evaluated with the selected trace-gas method.

Trace gas vs other leak test methods

Highlighted row is this method. ✓ yes · × no
MethodNon-destructiveNeeds an access portLocates the leakTypical use
Pressure decay✓✓×Sealed parts with a port
Vacuum decay✓✓×Parts and packaging
Mass flow✓✓×Flow-rate limits
Occlusion✓✓×Blocked passages
Burst×✓×Failure pressure
Pressure cracking✓✓×Valve opening pressure
Chamber✓××Sealed parts, no port
Sniffing✓✓✓Finding the leak site
Hard vacuum✓✓×Hermetic, safety-critical parts
Accumulation✓✓×Large parts, total leak rate
Bombing✓××Sealed parts, no fill port
Differential pressure✓✓×Large volumes, low leak rates
Trace gas✓✓✓Very small leaks, quantified

Trace gas leak test FAQ

What is trace gas leak testing?

It fills a sealed part with an identifiable gas and measures the gas that escapes.

Which gases can be used?

Helium, hydrogen forming gas, argon and clean dry air can be used as trace gases.

Why use helium?

Helium is inert, non-toxic and non-flammable, with low atmospheric background and a small molecule.

What is forming gas?

Forming gas is 5% hydrogen in 95% nitrogen and can be used for high-throughput sniff detection.

Can trace gas locate a leak?

Yes. Sniffing measures escaping trace gas along seams, joints and fittings to identify the leak site.

Which method is most sensitive?

Helium hard vacuum testing resolves 10⁻⁹ to 10⁻¹¹ mbar·l/s.

Can trace gas use air?

Compatible instruments can use clean, dry compressed air and reach roughly 10⁻⁴ mbar·l/s.

Ready to Ensure Product Integrity ?

Request for Quote

Trace gas is a peer to air-based methods. Compare the options in the leak test method chooser and read the pressure-decay buyer’s guide for the air-based route.

For HVAC and refrigeration components, see HVAC & Refrigeration Leak Testing for peer air and trace-gas production method routing.

Trace gas is a peer to air-based methods. Compare the options in the leak test method chooser and read the pressure-decay buyer’s guide for the air-based route.

Plan the test boundary with the Leak Test Fixture Design Guide and review IP67 / IP68 production leak testing for ingress-driven enclosure programs.